Vlamdover 85-10
Standaard vlamdover volgens de DIN EN ISO 5175-1 voor verhoogde flow
- hoogste kwaliteit van de wereldmarktleider
- beveiligingselementen: vlamdover [FA], thermisch gestuurde afsluiter [TV], gaskeerklep [NV], filter in de gasingang
- ieder appendage wordt 100% getest
- BAM gecertificeerd
- 34 X 106 mm, 434 g
- Acetyleen max. 22 m³/h vrije uitstroom)
- Bandbare gassen max. 235 m³/h (vrije uitstroom)
- Zuurstof max. 310 m³/h (vrije uitstroom)
Dit model is ook in RVS leverbaar
Informatie
WITT Flashback Arrestors for reliable protection against dangerous reverse gas flow and flashbacks in accordance with DIN EN ISO 5175-1. Every Arrestor 100% tested.
The best Flashback Arrestors in the world
- a large surface area flame arrestor FA of stainless steel construction extinguishes any dangerous flashback entering the device in any direction
- a temperature-sensitive cut-off valve TV extinguishes sustained flashbacks long before the internal temperature of the arrestors reaches a dangerous level (not for FA E460)
- a spring-loaded non-return valve NV prevents slow or sudden reverse gas flow forming explosive mixtures in the gas supply
- a filter at the gas inlet protects the arrestor against dirt contamination, extending the service life
Operation / Usage:
- Flashback Arrestors are used to protect gas cylinders and pipeline outlet points (hoses and any equipment) against dangerous reverse gas flow and flashbacks
- for pipeline outlets and single cylinders with high-consumption users
- WITT Flashback Arrestors may be mounted in any position /orientation
- only one piece of equipment may be connected to a single Flashback Arrestor
- the maximum ambient / working temperature is 60 °C / 140 °F
- gases: acetylene, town gas, natural gas, LPG, hydrogen, oxygen, compressed air, ethylene (more upon request)
Maintenance:
- annual testing of the non-return valve, body leak tightness and flow capacity is recommended
- WITT is happy to supply special test equipment
- Flashback Arrestors are only to be serviced by the manufacturer.
- The dirt filter may be replaced by competent staff
Approvals:
Company certified to ISO 9001 and PED 2014/68/EU Module H
CE-marked according to PED 2014/68/EU
Cleaned for Oxygen Service according to EIGA IGC Doc 13/12/E: Oxygen Pipeline and Piping Systems